<?xml version="1.0" encoding="UTF-8"?>
<doi_batch version="5.3.1" xmlns="http://www.crossref.org/schema/5.3.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1" xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" xsi:schemaLocation="http://www.crossref.org/schema/5.3.1 http://www.crossref.org/schema/deposit/crossref5.3.1.xsd">
 <head>
  <doi_batch_id>aspg-18-3882-1792501924</doi_batch_id>
  <timestamp>20261020131204</timestamp>
  <depositor>
   <depositor_name>American Scientific Publishing Group</depositor_name>
   <email_address>admin@americaspg.com</email_address>
  </depositor>
  <registrant>American Scientific Publishing Group</registrant>
 </head>
 <body>
  <journal>
   <journal_metadata language="en">
    <full_title>Journal of Intelligent Systems and Internet of Things</full_title>
    <abbrev_title>JISIoT</abbrev_title>
    <issn media_type="print">2769-786X</issn>
    <issn media_type="electronic">2690-6791</issn>
   </journal_metadata>
   <journal_issue>
    <publication_date media_type="online">
     <year>2025</year>
    </publication_date>
    <journal_volume>
     <volume>17</volume>
    </journal_volume>
    <issue>2</issue>
   </journal_issue>
   <journal_article publication_type="full_text">
    <titles>
     <title>Designing Explainable Deep Learning Models for Biomedical Data Analysis and Clinical Prediction Enhancement</title>
    </titles>
    <contributors>
     <person_name sequence="first" contributor_role="author">
      <given_name>Maha</given_name>
      <surname>Rahrouh</surname>
      <affiliations>
       <institution>
        <institution_name>Business Department, Al Ain University, Al Ain, UAE</institution_name>
       </institution>
      </affiliations>
     </person_name>
     <person_name sequence="additional" contributor_role="author">
      <given_name>Walid</given_name>
      <surname>Alayash</surname>
      <affiliations>
       <institution>
        <institution_name>Computer Technology Engineering Department, Engineering Technologies College, Al-Esraa University Baghdad, 1008, Iraq</institution_name>
       </institution>
      </affiliations>
     </person_name>
     <person_name sequence="additional" contributor_role="author">
      <given_name>Inas salah</given_name>
      <surname>Mahmoud</surname>
      <affiliations>
       <institution>
        <institution_name>Biomedical Engineering Department, Engineering College, Al-Esraa University Baghdad, 10081, Iraq</institution_name>
       </institution>
      </affiliations>
     </person_name>
     <person_name sequence="additional" contributor_role="author">
      <given_name>Marwa Hussien</given_name>
      <surname>Moahmed</surname>
      <affiliations>
       <institution>
        <institution_name>Computer Technology Engineering Department, Engineering Technologies College, Al-Esraa University Baghdad, 1008, Iraq</institution_name>
       </institution>
      </affiliations>
     </person_name>
    </contributors>
    <jats:abstract>
     <jats:p>Recent advancements in biomedical data analysis have significantly transformed clinical decision-making. However, the inherent complexity and heterogeneity of healthcare data continue to present major challenges. Traditional deep learning models, while powerful, often lack transparency, limiting their adoption in clinical settings due to their &quot;black-box&quot; nature. To address this critical gap, this study introduces a novel Explainable Deep Learning (XDL) framework that integrates high predictive accuracy with interpretability, enabling clinicians to trust and validate AI-driven insights. The proposed framework leverages advanced interpretability techniques—such as Grad-CAM for visual attribution and SHAP for feature importance analysis—to analyze multimodal biomedical data, including clinical imaging, genomic sequencing, and electronic health records. Experimental evaluations across three benchmark datasets demonstrated the model’s strong performance, achieving an accuracy of 91%, sensitivity of 95.4%, specificity of 98.6%, and an AUC of 99%, while maintaining an interpretability score of 92% as rated by domain experts. Compared to non-explainable models, the proposed approach showed a 12.3% increase in interpretability and a 5.8% improvement in accuracy. Importantly, attention map analysis revealed alignment with clinically relevant biomarkers in 93% of cases and uncovered previously overlooked prognostic patterns in 18% of patient cohorts. These findings underscore the model’s potential to enhance diagnostic precision and support more informed clinical decisions. Moreover, the algorithm reduced diagnostic time by 23% due to its provision of actionable insights. The hybrid approach—combining built-in attention mechanisms with external interpretability tools—ensures seamless integration into clinical workflows while supporting compliance with regulatory standards for transparency.</jats:p>
    </jats:abstract>
    <publication_date media_type="online">
     <year>2025</year>
    </publication_date>
    <pages>
     <first_page>88</first_page>
     <last_page>100</last_page>
    </pages>
    <publisher_item>
     <item_number item_number_type="article-number">3882</item_number>
    </publisher_item>
    <ai:program name="AccessIndicators">
     <ai:license_ref applies_to="vor">https://creativecommons.org/licenses/by/4.0/</ai:license_ref>
    </ai:program>
    <doi_data>
     <doi>10.54216/JISIoT.170207</doi>
     <resource>https://www.americaspg.com/journal/18/article/3882</resource>
     <collection property="text-mining">
      <item>
       <resource mime_type="application/pdf">https://www.americaspg.com/storage/61749663496.pdf</resource>
      </item>
     </collection>
    </doi_data>
   </journal_article>
  </journal>
 </body>
</doi_batch>
