<?xml version="1.0" encoding="UTF-8"?>
<doi_batch version="5.3.1" xmlns="http://www.crossref.org/schema/5.3.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1" xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" xsi:schemaLocation="http://www.crossref.org/schema/5.3.1 http://www.crossref.org/schema/deposit/crossref5.3.1.xsd">
 <head>
  <doi_batch_id>aspg-22-4426-1791483625</doi_batch_id>
  <timestamp>20261008182025</timestamp>
  <depositor>
   <depositor_name>American Scientific Publishing Group</depositor_name>
   <email_address>admin@americaspg.com</email_address>
  </depositor>
  <registrant>American Scientific Publishing Group</registrant>
 </head>
 <body>
  <journal>
   <journal_metadata language="en">
    <full_title>International Journal of BIM and Engineering Science</full_title>
    <abbrev_title>IJBES</abbrev_title>
    <issn media_type="electronic">2571-1075</issn>
   </journal_metadata>
   <journal_issue>
    <publication_date media_type="online">
     <year>2026</year>
    </publication_date>
    <journal_volume>
     <volume>12</volume>
    </journal_volume>
    <issue>2</issue>
   </journal_issue>
   <journal_article publication_type="full_text">
    <titles>
     <title>OccuTwin: Occupancy-Predictive HVAC Optimisation through Deep Learning and a BIM-Coupled Digital Twin</title>
    </titles>
    <contributors>
     <person_name sequence="first" contributor_role="author">
      <given_name>Anwar</given_name>
      <surname>Shanwan</surname>
      <affiliations>
       <institution>
        <institution_name>Doctor in Mechanical Engineering, Researcher at University of Orléans, France</institution_name>
       </institution>
      </affiliations>
     </person_name>
     <person_name sequence="additional" contributor_role="author">
      <given_name>Mariam</given_name>
      <surname>Altaema</surname>
      <affiliations>
       <institution>
        <institution_name>PhD Candidate, Faculty of Natural Sciences and Engineering, Ankara Yıldırım Beyazıt University, Ankara, Türkiye</institution_name>
       </institution>
      </affiliations>
     </person_name>
     <person_name sequence="additional" contributor_role="author">
      <given_name>Raphaël</given_name>
      <surname>Omran</surname>
      <affiliations>
       <institution>
        <institution_name>Mechanical Engineering, University of Rennes, France</institution_name>
       </institution>
      </affiliations>
     </person_name>
    </contributors>
    <jats:abstract>
     <jats:p>Buildings account for nearly 40% of global final energy consumption, with heating, ventilation, and air conditioning systems responsible for the largest single share of that load. Conventional schedule-based HVAC controllers operate on fixed occupancy assumptions and are consequently unable to exploit the predictable but irregular occupancy patterns that characterise modern working environments. This paper proposes OccuTwin, an integrated framework that couples multi-step occupancy forecasting with a BIM-based digital twin to enable genuinely predictive HVAC optimisation. Four sequence models—Long Short-Term Memory, Gated Recurrent Unit, XGBoost with lag features, and a Temporal Fusion Transformer—are trained on the publicly available Mind Your Building occupancy dataset and the multi-building Building Data Genome Project benchmark to predict room-level occupancy at five-minute resolution. The best-performing Transformer model achieves 94.8% accuracy and an improved weighted F1- score on the 30% hold-out set, outperforming the LSTM baseline by 1.4 percentage points. An IFC-coupled co-simulation environment links real-time occupancy predictions to a virtual HVAC thermal model implemented in EnergyPlus, enabling zone-level set-point optimisation driven by predicted rather than sensed occupancy. Annual co-simulation across nine building zones documents 21.2% energy savings over a schedule-based rule controller while simultaneously improving the fraction of time within ASHRAE thermal comfort bounds from 92.4% to 97.2%. Ablation experiments identify temporal lag features and SMOTE-based class rebalancing as the two most critical preprocessing choices, and noise-injection tests confirm that the Transformer retains 95.1% accuracy under 15% sensor noise—a critical property for edge-deployed IoT environments.</jats:p>
    </jats:abstract>
    <publication_date media_type="online">
     <year>2026</year>
    </publication_date>
    <pages>
     <first_page>66</first_page>
     <last_page>80</last_page>
    </pages>
    <publisher_item>
     <item_number item_number_type="article-number">4426</item_number>
    </publisher_item>
    <ai:program name="AccessIndicators">
     <ai:license_ref applies_to="vor">https://creativecommons.org/licenses/by/4.0/</ai:license_ref>
    </ai:program>
    <doi_data>
     <doi>10.54216/IJBES.120209</doi>
     <resource>https://www.americaspg.com/journal/22/article/4426</resource>
     <collection property="text-mining">
      <item>
       <resource mime_type="application/pdf">https://www.americaspg.com/storage/articles/manuscripts/01KVKAABRGCRJ6W1FFM45BEY1X.pdf</resource>
      </item>
     </collection>
    </doi_data>
   </journal_article>
  </journal>
 </body>
</doi_batch>