<?xml version="1.0" encoding="UTF-8"?>
<doi_batch version="5.3.1" xmlns="http://www.crossref.org/schema/5.3.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1" xmlns:ai="http://www.crossref.org/AccessIndicators.xsd" xsi:schemaLocation="http://www.crossref.org/schema/5.3.1 http://www.crossref.org/schema/deposit/crossref5.3.1.xsd">
 <head>
  <doi_batch_id>aspg-22-961-1791483717</doi_batch_id>
  <timestamp>20261008182157</timestamp>
  <depositor>
   <depositor_name>American Scientific Publishing Group</depositor_name>
   <email_address>admin@americaspg.com</email_address>
  </depositor>
  <registrant>American Scientific Publishing Group</registrant>
 </head>
 <body>
  <journal>
   <journal_metadata language="en">
    <full_title>International Journal of BIM and Engineering Science</full_title>
    <abbrev_title>IJBES</abbrev_title>
    <issn media_type="electronic">2571-1075</issn>
   </journal_metadata>
   <journal_issue>
    <publication_date media_type="online">
     <year>2021</year>
    </publication_date>
    <journal_volume>
     <volume>4</volume>
    </journal_volume>
    <issue>1</issue>
   </journal_issue>
   <journal_article publication_type="full_text">
    <titles>
     <title>Skylight as a Passive Design Strategy in Tunisian Dwelling Using BIM Technology</title>
    </titles>
    <contributors>
     <person_name sequence="first" contributor_role="author">
      <given_name>Habiba Benzarti ep</given_name>
      <surname>Ghedas</surname>
      <affiliations>
       <institution>
        <institution_name>Superior Technical School of Architecture at Barcelona (ETSAB), Polytechnic University of Catalonia (UPC), Barcelona, Spain; Laboratory Studies of Thermal and Energy Systems, LESTE, Engineer</institution_name>
       </institution>
      </affiliations>
     </person_name>
    </contributors>
    <jats:abstract>
     <jats:p>In Tunisia, energy saving in construction has become a necessity. Currently, it occupies third place of 27% of the final national consumption. It will be the first in the head with a percentage of 33% in 2030. The decision-making of the climatic parameters at the preliminary design stage by the designer can reduce CO2 production and improve energy conservation. Therefore, the solar design must take advantage of solar radiation in an arid climate. A horizontal glass surface known as passive solar heating in the winter in which contributes to heating the space and reducing artificial lighting. This paper focuses to study skylight design using Revit architecture. The two conceptual mass modes with separated and grouped skylight are investigated. This study is based on based on Energy Use Intensity, Annual Energy Cost, and Life Cycle Energy Cost parameters to assess performance energetic and environmental of skylight system. The found results show that the skylight system improves the energy efficiency and life cycle of the building only if certain parameters of design are considered.</jats:p>
    </jats:abstract>
    <publication_date media_type="online">
     <year>2021</year>
    </publication_date>
    <pages>
     <first_page>18</first_page>
     <last_page>25</last_page>
    </pages>
    <publisher_item>
     <item_number item_number_type="article-number">961</item_number>
    </publisher_item>
    <ai:program name="AccessIndicators">
     <ai:license_ref applies_to="vor">https://creativecommons.org/licenses/by/4.0/</ai:license_ref>
    </ai:program>
    <doi_data>
     <doi>10.54216/IJBES.040102</doi>
     <resource>https://www.americaspg.com/journal/22/article/961</resource>
     <collection property="text-mining">
      <item>
       <resource mime_type="application/pdf">https://www.americaspg.com/storage/31775424606.pdf</resource>
      </item>
     </collection>
    </doi_data>
   </journal_article>
  </journal>
 </body>
</doi_batch>
